Put on the appropriate personal protective equipment.
|
 |
 |
Clean the filter, nozzles and tank, and check the pressure gauge and pump. Make sure there are no leaking hoses or fittings.
|
 |
 |
Measure the swath width.This is the boom width plus the distance between the two nozzles in metres.
|
 |
 |
Fill tank with clean water and prime spray unit to operating pressure.
|
 |
 |
Measure the amount of liquid put out by each nozzle over one minute. Change any faulty nozzles and record the total output in litres of all the nozzles combined.
|
 |
 |
Record the time in seconds it takes to travel 100 metres:
|
Speed =
|
360
|
 |
 |
|
(km/hr)
|
time (seconds)
|
|
 |
 |
Calculate the spray application rate:
|
=
|
600
|
x
|
output (litres/min)
|
 |
 |
 |
 |
|
|
swath (m)
|
|
speed (km/hr)
|
|
 |
 |
Calculate amount of fertiliser you need to add to tank:
|
Tank capacity (litres) x fertiliser
rate/ha (Kg)
|
 |
|
Spray application rate (litres/ha)
|
|
 |